LTE: Measurement Report

Direction: UE => E-UTRAN
Signalling Radio Bearer: SRB1
RLC Mode: AM
Logical Channel: DCCH
Transport Channel: UL-SCH

The UE reports measurement information in accordance with the measurement configuration as provided by E-UTRAN. E-UTRAN provides the measurement configuration applicable for a UE in RRC_CONNECTED by means of dedicated signalling, i.e. using the RRC CONNECTION RECONFIGURATION message

The UE can be requested to perform the following types of measurements:
  • Intra-frequency measurements: Measurements at the downlink carrier frequency (ies) of the serving cell(s).
  • Inter-frequency measurements: Measurements at frequencies that differ from any of the downlink carrier frequency (ies) of the serving cell(s).
  • Inter-RAT measurements of UTRA frequencies or of GERAN frequencies or of CDMA2000 HRPD or CDMA2000 1xRTT frequencies

Example: MEASUREMENT REPORT message – Intra E-UTRAN measurements












Example: MEASUREMENT REPORT message – InterRAT measurements




















Reference: 3GPP TS 36.331

15 comments:

  1. Hi ,
    i'd like to thank you for your efforts,
    regards the above measurements the RSRP & RSRQ is absolute values how can we get the dbm values
    is it like
    RSRP (-140 + 56) = - 84 dbm
    RSRQ (-40 + 26) = -14 db

    thnkx in advance.

    ReplyDelete
  2. Hi,

    According to Table 9.1.4-1 (TS 36.133), RSRP of 56 = -85 ≤ RSRP < -84 dBm
    and
    According to Table 9.1.7-1 (TS 36.133), RSRQ of 26 = -7 ≤ RSRQ < -6.5 dB

    Do you agree?

    ReplyDelete
    Replies
    1. Hello

      How to identify the primary cell?
      For example I see the following below however no PCI or frequency identifier.

      message: c1: measurementReport: MeasurementReport ::= {
      criticalExtensions: c1: measurementReport-r8: MeasurementReport-r8-IEs ::= {
      measResults: MeasResults ::= {
      measId: 2
      measResultPCell: measResultPCell ::= {
      rsrpResult: 21
      rsrqResult: 10

      Delete
  3. thank you for your prompt response.
    and i'm totally agree with you

    BR,
    Hossam

    ReplyDelete
  4. Hi

    can any point in time it can be possible that ue may report two meas_id in one measurement report?
    I mean that for meas_id = 1 say it sends everything PCI and meas results,can in the same report UE simply report meas_id with rsrp and rsrq results?

    ReplyDelete
  5. RSRP (-140 + 56) = - 84 dbm 
    RSRQ (-19.5 + 26) = -6.5 db

    ReplyDelete
  6. HI.. Thanks for the explanation.. When UE will send the measurement report apart from meas config provided by network? Periodically?

    ReplyDelete
  7. HI can you tell the difference between RRC reconfiguration and RRC restablishment. and any example scenario.

    ReplyDelete
    Replies
    1. RRC CONFIGURAGATION WILL BE USE IN CONNECTED IF U ALREADY CONNECTED TO NETWORK....THEN YOU NEED MORE RESOURCE FOR DWONLAODING MOVIE, ETC THEN OUR RADIO RESOURCE WILL BE MODIFIED THEN HERE WILL USE RRC CONFIGURATION, AND IF RRRC CONFIGURATION FAIL DUE TO UE NOT HAVING VALID CONTEXT INFO , IF HANDOVER FAIL , MOBILITY EUTRAN COMMAND FAIL ....THEN AGAIN NEED TO RESTABLISH RRC CONNECTION THEN HERE WILL USE FOR RRC CONNECTION REESTABLISHMEN TPROCEDURE

      Delete
  8. Hi
    can u Please explain how UE decides periodicity of measurement reports it sends to eNB.

    ReplyDelete
  9. A2 report is triggered only when the serving cell become worst than the thresholdd value which is defined in the Sib1

    ReplyDelete
  10. Hello,

    Greetings!!!

    We’re working on an internal testing to evaluate the signal strength and quality information across access technologies.
    We obtain the Signal strength and quality from the UICC by issuing the PLI-NMR proactive command using Intra-frequency measurements to the UE.

    Ideally, we should get the following data:
    • For UTRAN
    o Access Tech: UTRAN
    Data: 220000192D6B10
    Parsing:
    UL-DCCH-Message
    message: measurementReport (8)
    measurementReport
    measurementIdentity: 1
    measuredResults: intraFreqMeasuredResultsList (0)
    intraFreqMeasuredResultsList: 1 item
    Item 0
    CellMeasuredResults
    modeSpecificInfo: fdd (0)
    fdd
    primaryCPICH-Info
    primaryScramblingCode: 150
    cpich-Ec-N0: 45
    cpich-RSCP: 49
    • For E-UTRAN
    o Access Tech: E-UTRAN
    Data: 0810234405E5A76C
    Parsing:
    UL-DCCH-Message
    message: c1 (0)
    c1: measurementReport (1)
    measurementReport
    criticalExtensions: c1 (0)
    c1: measurementReport-r8 (0)
    measurementReport-r8
    measResults
    measId: 1
    measResultPCell
    rsrpResult: -106dBm <= RSRP < -105dBm (35)
    rsrqResult: -11.5dB <= RSRQ < -11dB (17)
    measResultNeighCells: measResultListEUTRA (0)
    measResultListEUTRA: 1 item
    Item 0
    MeasResultEUTRA
    physCellId: 377
    measResult
    rsrpResult: -102dBm <= RSRP < -101dBm (39)
    rsrqResult: -6.5dB <= RSRQ < -6dB (27)

    However, we do not get the signal strength and quality from the decoded data.
    • For UTRAN
    o Access Tech: UTRAN
    Data: 8000869E488834A9E3E000
    Parsing:
    UL-DCCH-Message
    integrityCheckInfo
    messageAuthenticationCode: 00010d3c [bit length 32, 0000 0000 0000 0001 0000 1101 0011 1100 decimal value 68924]
    rrc-MessageSequenceNumber: 9
    message: cellChangeOrderFromUTRANFailure (2)
    cellChangeOrderFromUTRANFailure: r3 (0)
    r3
    cellChangeOrderFromUTRANFailure-r3
    rrc-TransactionIdentifier: 0
    dummy
    integrityProtectionModeCommand: startIntegrityProtection (0)
    startIntegrityProtection
    integrityProtInitNumber: 6953c7c0 [bit length 32, 0110 1001 0101 0011 1100 0111 1100 0000 decimal value 1767098304]
    interRAT-ChangeFailureCause: configurationUnacceptable (0)
    configurationUnacceptable: NULL
    • For E-UTRAN
    o Access Tech: E-UTRAN
    Data: 02060B00BCB5AB80
    Parsing:
    UL-DCCH-Message
    message: c1 (0)
    c1: csfbParametersRequestCDMA2000 (0)
    csfbParametersRequestCDMA2000
    criticalExtensions: csfbParametersRequestCDMA2000-r8 (0)
    csfbParametersRequestCDMA2000-r8
    nonCriticalExtension


    Other data that we are getting is present below:
    Data: 02050B0A63BC311BEE41466B8E31A2E2009EB4051AECE120, 0204E8069EB4871AED09A61B46618ED114, 0203670466B3669AECD189EB3030

    Kindly, advise on the same

    ReplyDelete
  11. How frequently eNB ask for measurement report? Which parameter decide it

    ReplyDelete
  12. A measurement report is a document that provides detailed information about the results of measurements or assessments. Stream Unwatchable Lag It includes data, analyses, and any relevant findings.

    ReplyDelete